รายละเอียดสินค้า
Optical Interface Source ................................................................................ MLM Laser* Wavelength......................................................................... 1310?50 nm* Minimum output power ............................................................... -15dBm Code................................................................................ scrambled NRZ Fibre type................................................................................... SMF Receiver .................................................................................... PIN-FET Receive sensitivity ...................................................................... -34dBm Maximum receive power.............................................................. 0dBm System gain..................................................... >19 dB (at 1x10-10BER)** Protection (option) .................................................................... 1+1 APS * There are also 1550nm wavelength and SLM for your application. ** System gains >25dB or others are available too. E1 Interface (TEM/G.703 and FTEM/G.704) Data rate..................................................................... 2048kbps?50ppm Line code ............................................................................. HDB3/AMI* ProMUX-600 User Manual V4.21 Frame format ....................................................... Transparent (for TEM) Structured/Unstructured* (for FTEM) Impedance............................................................... 75/120?5% ohms** Pulse shape......................................................................... ITU-T G.703 Line loss tolerance........................................................ >6dB at 1024 KHz (Apply 215-1pattern and error free for over 15minutes) Minimum return loss at input port .......................... 12dB for 51 to 102 KHz 18dB for 102 to 2048 KHz 14dB for 2048 to 3072 KHz Performance ................................................................. ITU G.821/G.826 Jitter....................................................................................ITU-T G.823 * Field selectable by management interfaces ** It is field selectable by management interfaces for TEM, but should be specified on order for FTEM. T1 Interface (TEM/G.703 and FTEM/G.704) Data rate..................................................................... 1544kbps?50ppm Line code ............................................................................. B8ZS/AMI* Frame format ....................................................... Transparent (for TEM) SF/ESF/Unframed* (for FTEM) Impedance........................................................................100?5% ohms Cable length compensation (LBO).............................................. 0~200M* Pulse shape................................................................ ITU-T G.703/ANSI Power level .....................................................12.6~17.9dBm at 772 KHz The power level at 1.544MHz is at least 29dB below at 772 KHz (For an all-ones transmitted patter, and in a band no wider than 3 KHz) Performance ............................................................... ITU G.821/G.826 Jitter...................................................................................ITU-T G.824 < 1/3UI peak to peak * Field selectable by management interfaces Ethernet Interface (ETHM/QETHM) Data rate................................................................ 10/100Mbps Base T Protocol .................................................................. IEEEE802.3/802.3u V.35 Interface (QV35M) ProMUX-600 User Manual V4.21 Data rate................................................................. nx64K bps, n=1~32 Line code ...................................................................................... NRZ Clock sources ..................................................... Remote, Loop, Internal Control signals................................................................ DSR, CTS, DCD System Capacity High speed slot.................................................................................. 2 Low speed slot................................................................................... 4 OIM...................................................................................... 1 channel TEM................................................................ 4 channels T1/E1 (G.703) FTEM.............................................................. 4 channels T1/E1 (G.704) T1/E1...................................................................... 4/8/12/16 channels ETHM ........................................................ 1 channel 10/100M Ethernet QETHM..................................................... 4 channels 10/100M Ethernet QV35M ........................................................................ 4 channels V.35
Craft Interface Physical layer ............................................................................ RS232 Data rate............................................................................ 115,200bps Operation mode................................................................. menu-driven OS Interface Physical layer ................................................................... 10/100BaseT Protocol ..................................................................................... SNMP Operation mode.............................................................................. GUI Connectors Optic ........................................................................... SC/PC or FC/PC T1/E1..................................................................... D-sub 25-pin female (Provide grounding pins for symmetrical pair grounding at input/output) (Provide converter for wire-wrap connection or module for BNC) RS232.................................................................... D-type 9-pin female LAN............................................................................................. RJ45 V.35 ..................................................................... D-sub 78-pin female (Provide convert cable for M34 male or female connector to 4 V.35 ports)
ProMUX-600 User Manual V4.21 Office alarm............................................................ D-type 9-pin female DC power................................................................................... Screw Electricity Power Source DC input.............................................................................. -36 ~ -75V AC input............................................................. 90~240Volt?47~63Hz Redundancy (with DC and DC power sources) ...................... load sharing Power consumption .................................................................... <15W Mechanical Size Height ...................................................................................... 44mm Width ..................................................................................... 440mm Depth...................................................................................... 300mm (Mount on 19 or 23 inches or ETSI rack) LED Indicators Front panel PWR-power indicator RDI-remote defect (alarm) indicator MNT-loopback status indicator CR-critical alarm indicator, MJ-major alarm indicator, MN-minor alarm indicator ACO-Alarm Cut Off indicator Trib Status-tributary status and alarms (such as 16 T1/E1) Ethernet status indicators (OS LAN) OIM Panel PWR-power indicator WK-working line indicator RDI-remote receive failure indicator RF-receive failure indicator TEM/FTEM Panel PWR-power indicator 1/2/3/4-T1/E1 mode indicator ETHM Panel PWR-power indicator FLT-not used ProMUX-600 User Manual V4.21 WK-module under in-service mode Ethernet status indicators QV35M Panel TD/RD V.35 interface transmit and receive indicators Push Button RST-reset system ACO-alarm cut off ESC/ENT+/?/?-LCD control keypads (when equipped with LCD) LCD (optional) 16x2 liquid crystal display with 4 keypads Office Alarm Visible-critical, major, and minor Audible-critical, major, and minor Environment Conditions Temperature .......................................................................... 0~60?C Humidity............................................. up to 95%?without condensation EMI .................................................................... FCC/CISPR 22 Class A EMC..................................................................................... EN50082-1 MTBF................................................................................... >40000hrs |